Medicare
General Information
Details
No files uploaded for this product
File Name DWG PDF
Montage
Bandraster 75mm - PDF
Bandraster 50mm - PDF
File Name DOC XLSX PDF
Documents
Deckon Bandraster Ds En
Rockfon Teknik Şartnameler Medicare Standard - Word
File Name DOC XLSX PDF
Documents
CAD&PDF
Assembly content is being prepared
Şartnameler Rockfon Medicare Standard - PDF
Projects Using Product
Rockfon Medicare Standart Datasheet - PDF
BSI EMS 570949 Certificate of Registration Environmental Management System ISO 14001_2004 01-jul-2014 CIG
Certyfikat_ISO 9001_Rockwool_eng_122015
certyfikat_iso-9001_rockwool_eng_122015
datasheet_exp_medicare_01.2014
+
LCW Genel Müdürlük
Hizmet Binası
Description
Aesthetic acoustic ceiling solution for areas with essential hygiene and cleaning requirements.
MediCare Standard is a cost-effective solution for areas with essential hygiene and cleaning requirements, such as administration, waiting areas and nursing offices. It offers high sound absorption to provide acoustic comfort to personnel, patients and visitors. MediCare Standard has obtained the Bacteriological Class B5 and B10, which fulfils the requirements of the very high-risk zones as defined in NF S 90-351. MediCare Standard does not contribute to the growth of MRSA. It has a low particle emission resulting in Clean Room Classification ISO Class 5. MediCare Standard can be easily cleaned with a dry or damp cloth.
MediCare Standard is an acoustic ceiling made of a 12-15 mm stone wool panel. The visible surface is covered with a white painted fleece providing an aesthetically pleasing finish. The rear side of the panel is covered by a back fleece. The edges are painted.
Acoustics – Sound absorption
Sound absorption has been measured in accordance with ISO 354. Sound absorption data ap, aw and absorption class are calculated in accordance with ISO 11654. Noise Reduction Coefficient (NRC) is calculated in accordance with ASTM C423.
Sound absorption :
αw: 0.85 and
NRC: 0.80
Fire Performance
General:
Rockfon ceiling tiles have a core of stone wool. Stone wool is noncombustible with a melting point of more than 1000°C.
Reaction to fire:
Class A1 in accordance with EN 13501-1.
Fire protection:
The fire resistant properties of stone wool ensure Rockfon ceiling tiles provide fire protection in construction. The fire protection properties of Rockfon ceilings have been tested and classified in accordance with European norm EN 13501-2 and/or national norms depending on requirements in national building codes.
Humidity Resistance And Dimensional Stability (Flexural Tensile Strength)
Rockfon ceiling tiles are dimensionally stable even at humidity levels of up to 100% RH and can be installed at all temperatures ranging from 0ºC to 40°C.
No acclimatisation is necessary.
Sonar is predominantly classified as Class 1/C/0N in accordance with EN 13964. However, certain module sizes (width above 700mm) are Class 2/C/0N.
Clean Room Classification
Particles emitted by building materials can increase the risk of infection spreading in Healthcare buildings. Due to its low particle emission, MediCare Standard meets stringent requirements for air cleanliness. MediCare Standard is classified ISO Class 5 in accordance with ISO 14644-1, this corresponds with Class 100 of US Federal Standard 209E. The clean room classification of MediCare Standard fulfils the requirements of Zone 4 as defined in NF S 90-351.
Light Reflection
White, 85% diffuse light reflection in accordance with ISO 7724-2.
Cleaning
The surface of MediCare Standard has enhanced resistance. The surface can be vacuum cleaned with a soft brush attachment. It can also be cleaned using a damp cloth with cold or warm water (max. 40°C) with a slightly alkaline detergent (pH between 7 and 9) without alcohol, ammonia or chlorine.
Cleaning with a sponge or damp cloth may render the surface slightly shinier and we therefore recommend cleaning the whole surface evenly for best results.
Hygiene
Stone wool has no nutritional value and therefore it provides no sustenance to harmful micro-organisms.
MediCare Standard has been tested with the following micro-organisms and has obtained the bacteriological class B5 and B10, which fulfils the requirements of Zone 4 as defined in NF S 90-351:
– Methicillin Resistant Staphylococcus Aureus (MRSA): bacteria resistant to antibiotics and responsible for post-surgery infections and septicaemias.
– Candida Albicans: yeast responsible for skin infections and pneumonias.
– Aspergillus Niger: mould responsible for pneumonias.
Environment
A representative selection of Rockfon products have been awarded the Danish Indoor Climate Label and the Finnish Indoor Climate Label (M1).Medicare is recyclable.
FIN_ M1poster
ISO 14001_2004 Certificate of Approval Roermond 01-may-2014
ISO Certificate_English 2018
ISO9001-2008_Rockwool ROE
ISO9001-2015
ISO14001-2015
MediCare Standard CE
MediCare Standard CoC
RFN MediCare and Health segment 290715 - NS - PUB
RTS M1 Emission Classification of Building Materials 00-xxx-0000 valid until jan 2017